X-ray diagnostic complex for 2 workstations Calypso F (MTObs)
- Warranty 12-24 months
- Warranty free service and post-warranty
- Equipment instalation and staff training at the company's expense
- Full customer support (phone consultation even after installation)
- Visiting the exhibition hall
- Leasing sale
- Holding conferences and events
- Quick response to a request
X-ray machine for 2 working places Calypso F (MTObs)
Equipment:
- X-ray table MTObs with fixed height and table deck "floating" in 4 directions,
- high-frequency X-ray generator 50 kW,
- X-ray tube,
- X-ray vertical stand against the wall,
- high voltage cables.
DESCRIPTION:
CALYPSO F is an innovative multifunctional X-ray diagnostic system that is the most flexible solution in direct digital radiography. A highly integrated system that provides high-quality diagnostic results for trauma, emergency, routine and specialized examinations.
CALYPSO F is equipped with the OPERA D4000DR digital system, which provides high image quality and reduced patient dose.
This innovative DR system is offered in a variety of configurations, with a variety of generators and flat panel detectors, to meet any need - from emergency to trauma.
Main areas of application
- Emergency medicine
- General examinations
- Chest examination
- Diagnostics of bones and joints
SPECIFICATIONS: - The size of the tabletop is 220 x 80 cm.
- X-ray table MTOps Fixed Height
- Distance floor - surface 76 cm.
- Maximum patient weight 150 kg.
- Distance between table surface - film - 70 mm.
- The format of the cassettes used: 13x18 to 35x43.
- Vidsiyuyu grating 90 lines / inch, ratio 12: 1, focus 100 cm.
- Column: longitudinal movement 165 cm.
- Column: height 236 cm.
- Floor rail length 220cm
- Rotation release - foot pedal
- Focus-floor distance 53 - 193 cm.
- Rotation of the X-ray tube +/- 180 deg.
- Turn
High frequency 400kHz X-ray generator for radiography 50 kW.
- Operating voltage range 40 - 150
- The operating range of mA is from 10 to 630 mA.
- The range of operating values mAs is from 0.1 to 630 mAs.
- APR-anatomical programming of exposure parameters (768 programs).
- Exposure time: from 1 sec to 6.3 sec.
- Power supply: three-phase current 380/480 VAC +/- 10%, 50/60 Hz.
- Anode rotation speed 3000 / min.
- Extensive self-test.
Vertical stand of pictures.
- The sizes of the cassettes used are up to 35 x 43.
- Vidsiucha grille 90 lines / inch, ratio 12: 1, focus 180 cm.
- The range of vertical travel is 1490 mm.
- X-ray tube with rotating bifocal anode, focal spot 0.6 / 1.2 mm, maximum voltage 150 kV.