A safe and compact table-top device that makes it easy to dispose of used needles and syringes, thanks to the built-in burner and knife for cutting off the syringe cannula.
Manufacturer: MRK HEALTHCARE, India
Compared to mechanical needle destruction devices, where the needles are cut, but still remain sharp, infected and can cause infection to enter the body of a healthy person, Nulife DOTS burns the needle, disinfects it and destroys the syringe.
The device is mainly intended for use in laboratory conditions.
Principle of action:
The needle on the syringe is inserted into the hole on the upper surface of the device. The needle closes the upper, and located at a short distance from it, the lower electrode, as a result of which the needle heats up and begins to melt. The whole process, depending on the length and diameter of the needle, takes 2-3 seconds. The remains of destroyed needles in the form of metal pellets are collected in a separate container.
When using this device, observe the following safety rules:
1) Before connecting the device, check on the indicator whether the voltage of the device matches the voltage of the devices at your workplace.
2) Never immerse the cord and plug in water.
3) Turn off the appliance when not in use and before cleaning.
4) Turn off the appliance before removing the storage tray.
5) Clean the device from above, wiping it only with a soft dry cloth. After removing the storage tray, it must be cleaned with disinfection.
6) If the device requires an extension cord, then a 5A cord should be used. A cord marked with lower amperes can burn.
7) Add the device so that the wire does not interfere with the work.
8) The device is intended only for burning needles from 19g to 31g, with subsequent cutting of the cannula of the syringe. This device is not intended for the destruction of other metal objects. Do not try to destroy glass and metal syringes: this can lead to serious damage to the blade of the device.
9) Do not use the device in the presence of volatile gases and other volatile substances.
10) Do not insert your finger into the device.
11) For better protection, use a fuse that matches the fuse rating of the appliance.
12) Do not break the needle with a cutter.
13) Burn needles thinner than 19g in another machine.
14) Burn a maximum of 2 needles per minute.