Transcutaneous jaundice detector (bilirubinometer) BM-100A
- Warranty 12-24 months
- Warranty free service and post-warranty
- Equipment instalation and staff training at the company's expense
- Full customer support (phone consultation even after installation)
- Visiting the exhibition hall
- Leasing sale
- Holding conferences and events
- Quick response to a request
The transcutaneous jaundice detector (bilirubinometer) BM-100A is designed to measure the bilirubin level in the blood serum of newborns using a non-invasive transcutaneous method before, during and after a phototherapy session.
BM-100A is used during a dynamic clinical examination of newborns for initial screening to determine the degree of hyperbilirubinemia in newborns and to monitor the condition of newborns regarding the possible development of hyperbilirubinemia.
Features:
• The non-invasive transcutaneous method for measuring bilirubin levels in newborns provides effective screening and a significant reduction in the stress and pain load on newborns, which inevitably accompanies them during the collection of venous blood to determine the level of total bilirubin using an invasive method.
• Effective screening, confirmed by clinical studies, helps to reduce the frequency of rehospitalizations and the length of stay in medical institutions.
• Obtaining accurate results in a matter of seconds allows you to instantly diagnose the patient's condition and promptly make decisions regarding the need for phototherapy.
• 3.0-inch color touch screen provides display of measured numerical values on the screen in large font.
• Interface menu language – Ukrainian.
• Unit selection function (mg/dL or µmol/L).
• Average value measurement mode for increasing the accuracy of the measurement result is configured by the operator (2, 3, 4 or 5 measurements are available for calculating the average value).
• Date and time setting function.
• Screen auto-off function to save battery power.
• Screen brightness adjustment function.
• Saving and viewing 100 measurement results in the device memory.
• A fully charged built-in rechargeable battery provides at least 2000 measurements.
• Xenon flash lamp with a long service life (at least 150,000 measurements).
• The device base for convenient charging of the built-in rechargeable battery, equipped with test screens for checking the accuracy of measurements, saves time and money needed to diagnose the operability of the device.
• Does not require consumables.
• Convenient case for storing and transporting the product as standard.
Parameters
Display – 3.0-inch color touch
Measurement range – from 0 to 25.0 mg/dL (from 0 to 425 μmol/L)
Measurement accuracy – ± 1.5 mg/dL (± 25.5 μmol/L)
Power supply - Main unit: built-in rechargeable battery Li-Ion, 7.4 V, 1000 mAh, 7.4 Wh, fully charged built-in rechargeable battery provides at least 2000 measurements
Base (charging station): 12 V DC, 1.5A
Power adapter: 100-240 V~, 50/60 Hz
Light source - Xenon flash lamp
Light source resource - Not less than 150,000 flashes
Memory - Saving and viewing 100 measurement results
Check screen for testing the accuracy of measured values
[0]: Reference value 0-1.5 mg/dL
[20]: Reference value 18.5-21.5 mg/dL
Weight of main unit – ≤250 g
Dimensions of main unit – 60×41×175 mm
Weight of base unit – ≤250 g
Dimensions of base unit – 85×155×106 mm